Automatic Venting and Monitoring
System Type | Dry, Preaction |
Product Type | Monitoring - Corrosion & Gas Concentration |
Maximum Tube Length | 350 ft (107 m) each zone |
Vent Sample Connection | 5/32 in. (4 mm) push-connect flexible plastic tube quick connectors |
System Data at Your Fingertips
An advanced vent controller provides automatic oxygen venting and monitoring of nitrogen/oxygen concentration levels within each dry/preaction fire sprinkler system. Tyco offers two models: the TVC-2 and the TVC-6. One TVC-2 can control and monitor up to two (2) separate fire sprinkler systems, while the TVC-6 works with up to six (6) systems. The system can be easily monitored via the Human Machine Interface (HMI) display. The screen allows easy access to operation, maintenance, diagnostics and stored historical data.
Features
- Mounts to a wall inside the sprinkler valve room
- Interactive LCD touchscreen display
- Simplified troubleshooting with data logging and historical trends by zone
- Vent can be installed on the riser thanks to nitrogen generator fill-and-purge breathing method
- Provides pressure and nitrogen purity monitoring for up to two (TVC-2) or six (TVC-6) dry or pre-action systems (previously required one per system)
- Automated leak rate checks by zone
Benefits
Reduced Equipment Footprint
Unique technology eliminates the need for a nitrogen tank or refrigerated air dryer.
No Remote Equipment
Install the vent directly on the riser — no vents are needed at far points of the system.
Minimize Business Interruption
System leaks due to corrosion can lead to costly downtime — reducing corrosion helps keep systems healthy and operational.
Data At Your Fingertips
Instant access to historical data simplifies diagnostics to help keep systems operational.
Technical Specification
Power Supply | 120-240VAC/Single phase/50-60Hz, 0.5A | Vent Sample Connection | 5/32 in. (4 mm) push-connect flexible plastic tube quick connectors |
Temperature Rating | 32°F to 122°F (0°C to 50°C) | Maximum Tube Length | 350 ft (107 m) each zone |