- Tyco-Fire
- Products and Solutions
- Valves, Devices, and Components
- Wet System Valves and Components
- TD-2 Test and Drain Valve
TD-2 Test and Drain Valve
Globe-Style Design, Integrated Pressure Relief
Listings and Approvals | UL and C-UL Listed, FM Approved, Listed by California State Fire Marshall |
Pressure Rating | 310 psi (21,4 bar) - adjustable from 100 psi (6.9 bar) to 310 psi (21.4 bar) |
Sizes | 1¼ inch, 2 inch |
Reduce Leak Risk
The Model TD-2 test and drain valve offers a simpler way to test waterflow alarm devices and the draining of feed mains.
This valve features a linear shut-off to reduce leakage due to debris in media. It can be installed in any position, and uses self-cleaning sight glass to provide positive indication of flow.
Reduce the risk of a test and drain valve leak with the Model TD-2’s globe-style design and integrated pressure relief.

Features
- Included in the preassembled RM-2 riser manifold or available separately
- Integrated pressure relief
- Self-cleaning sight glass provides positive indication of flow
- Excess system pressure is exhausted internally through the drain outlet
- UL and C-UL Listed, FM Approved, Listed by California State Fire Marshall
- Reduces the risk of test and drain valve leaks with robust, globe-style design
- Installation in any position
- Adjustable range of 100 psi (6.9 bar) to 310 psi (21.4 bar)
- Available in two sizes/test orifices: 1¼-inch with a 2.8K orifice and 2-inch with a 4.2K orifice
Benefits

Reduce Leaks
The globe valve design of the TD-2 test and drain valve reduces wear and common leakage issues found with ball valve alternatives.

Maximize Flexibility
With its compact size, horizontal or vertical install, and configurable coupling assembly, the RM-2 provides maximum versatility

Increase Efficiency
Save time with a pre-assembled, tested, and ready-to-install solution that includes check and butterfly valves, flow switch, and test & drain valve
Related Products
Technical Specification
Sizes | 1¼ inch, 2 inch | Listings and Approvals | UL and C-UL Listed, FM Approved, Listed by California State Fire Marshall |
Pressure Rating | 310 psi (21,4 bar) - adjustable from 100 psi (6.9 bar) to 310 psi (21.4 bar) |
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next

SprinkCAD Software Suite
Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions.
Learn about our all-in-one software package